Alinco DJ-175 User Manual Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
8.Set Mode
8
44
8.3.7 Menu 7 TOT Penalty Time
This parameter determines the time to resume the transmission after the unit is forced
to quit transmitting by TOT.
1. TP-OFF is displayed on the LCD.
2. Rotate the dial to change the TOT Penalty Time setting.
Transmission is prohibited until the penalty time elapses.
• An alert beep sounds when the PTT key is pressed during the penalty time.
8.3.8 Menu 8 DTMF WAIT Time
Use this parameter to delay the time to start transmitting the DTMF tones in Auto
Dialer operation. The initial setting is 100ms.
1. DWT-01 is displayed on the LCD.
2. Rotate the dial to change the DTMF wait time setting.
8.3.9 Menu 9 DTMF Burst/Pause Time
This parameter determines the length of DTMF tones and pause time between the tones.
1. DP-60 is displayed on the LCD.
2. Rotate the dial to change the DTMF burst/pause time setting.
DP-60 DP-80 DP-160 DP-200
(unit: ms)
DWT-01 DWT-04 DWT-07 DWT-10
(unit: 100ms)
NOTE:
The following 3 menus explain the Auto Dialer DTMF tone parameters. Please
refer to the chart at the end for details.
TP-OFF TP-1 ----- TP-4 ----- TP-15
(unit: seconds)
Page view 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 59 60

Comments to this Manuals

No comments